Heights to be 8 above finished roof deck or as detailed.
Insulated roof curb detail.
Top of all roof curbs shall be level with pitch built into curb when deck slopes.
Pre fabricated fully assembled roof curbs will reduce installation time and costs by ensuring compatibility between the rooftop unit curb and roof openings.
Curbs should be a minimum of eight inches above the finished roof and factory insulated to reduce condensation.
Must be insulated see figure 5 or figure 12.
Specify prefabricated roof curbs and related products by a roof curb manufacturer not with or by the equipment manufacturer.
Roof opening for safety and sound considerations do not cut out the entire roof deck within the curb area.
Refer to figure 17 and tables 1 and 2 for specific center of gravity.
The bottom of the curb has a 2 flange out on all 4 sides to secure and seal up easily when roofing material is applied.
Free cad detail download of a prefabricated roof curb to be used in your architectural section cad drawings.
Curb installation should be a part of the roof deck not on top of insulation or roofing materials.
We use superior materials and hand welding techniques to create airtight seals.
The right insulated roof curb can mean fast installation saved time and money and a leak free roof penetration system at alta products llc we take pride in the quality and integrity of our work.
The rc insulated roof curb is formed and welded from 16ga galvanized material with a wood nailer attached to the top.
Specifications prefabricated roof curb to be manufactured of prime galvanized steel construction 20 18 16 or 14 gauge as required meeting astm a653 653m with welded corners and with seams joined by continuous water and air tight welds.
Internally insulated with 1 1 2 thick 3 lbs.
Pressure treated nailers should be provided by the curb manufacturer to receive roofing felts and eliminate noise transfer.
Curb installation should be a part of the roof deck not on top of insulation or roofing materials.
Roof curb shall be internally reinforced with angles 48 on center and factory installed wood nailer.
A rigid 1 1 2 3 insulation is attached to the inside of curb for thermal and acoustical properties.
Specify prefab roof curbs for use with all roof penetrations and roof mounted equipment including and not limited to hvac units duct openings pipe penetrations power roof exhauster intake and relief vents flues or job fabricated items.
Pressure treated nailers should be provided by the curb manufacturer to receive roofing felts and eliminate noise transfer.
Roof support the roof must be capable of adequately supporting the weight of the rooftop unit as well as that of the curb.