Trace the outline of the base of the rubber boot onto the metal roof with a pencil.
How to install a stove pipe through a roof.
Next using a 5 16 nut driver attach the chimney rain cap to the chimney pipe.
Place the chimney where it would be related to the stove and mark the center of the chimney on the ceiling.
Now that we are completed on the roof it s time to connect the single wall stove pipe to the insulated chimney pipe.
Attach the ends of the blocks to the joists using a pair of 1 1 2 inch wood.
Chimney planning step 2.
When installing a chimney for a wood stove on a metal roof you ll first need to assess the position.
A single wall pipe will require 18 inch clearance to the ceiling while double wall pipe needs an 8 inch clearance to the ceiling.
Flashings for steeper pitched roofs are available.
Transitioning from single wall black stove pipe to insulated double wall class.
Slide the rubber boot over the pipe to check the fit.
Seals penetration where pipe passes through roof.
The chimney pipe must protrude through the roof a minimum of 2 feet and it must be at least 10 feet away from the roof line.
Use in conjunction with storm collar part 6t sc to seal between flashing and vent pipe.
Drill a small hole in this spot to mark the chimney s center.
You will need to cut the opening to the roof to extend the chimney pipe.
Using a compass draw out the chimney s diameter.
What kinds of pipe we used how to assemble the s.
Position the blocks on edge between the joists and align the faces of each with the corresponding edges of the cutout.
Determine the number of chimney pipe lengths required the chimney must extend at least 3 feet above the highest point where it passes through the roof and be at least 2 foot higher than any part of the building within a horizontal distance of 10 feet figure 2.
A double wall pipe needs a 12 inch clearance space.
For roof pitches from 2 12 to 6 12.
This video shows you how we installed a stove pipe for our wood burning stove that is out in our pole barn.